Instructions manual DS series
21
The following operating modes can be selected using the dip-switches:
7.3.1. Absolute detection (see function 9 of Tab.1 at page 14)
The digital output (PNP) switches only if a certain object (dimensions
previously memorised) passes exactly in the desired position (Fig.13).
The analog output in this configuration is always active and the voltage
is proportional to the number of obscured optics (also non adjacent)
independently from the real switching of the digital output (PNP)
caused by the object detection.
Analog output PNP output Analog output PNP output
= 3V (4,5,6 channels) ON
3V (1, 2,3 channels) OFF
Analog output PNP output
= 5V ( 4, 5,6 ,7, 8 ch an nels) OFF
Fig. 13